Weifang diesel generatorgenerator tank scale, too much debris blocking water tank, ignition is not straight, can lead to generator overheating, heat effect and reduce the service life of the diesel generator set, so keep clear of diesel generating sets the scale inside the water tank, to ensure the normal operation of the diesel generator set plays a big role.

Specific operation method is: first of all, with 30 kg water 2.5 kg caustic soda and kerosene as cleaning fluid, 0.6 kg in the tank. Then start the engine, medium speed running off after about 10 minutes. For 10 to 12 hours after the restart, diesel engines, medium speed running down about 10 minutes, let out cleaning fluid. Join clean starting diesel engine cooling water, medium speed run clean on its own. So again and again 2 to 3 times, the scale can be completely cleared away. In this way will scale after rinse, knowledge take temporary solution not effect a permanent cure, should be added in the cooling water antifreeze and rust inhibitor to prevent the formation of scale.

Anyway, once found tanks in diesel generating sets have accumulated scale shall be removed in a timely manner after troubleshooting, lest on the operation of the diesel generator set caused irreparable accidents.